Ulnar Motor NCS Setup – above elbow

Setup – Ulnar Motor NCS

Electrode placement (use the bar electrode)

8-cm distance (black to black)

  • E1 (black):  Abductor digiti minimi (ADM) muscle (medial side of the hypothenar eminence)
  • E2 (red):  Distally along the little finger
  • Ground:  Dorsum of hand

Stimulation sites