Electrode placement (use the bar electrode)
- E1 (black): Behind the lateral malleolus
- E2 (red): Distally
- Ground: Lateral leg (between stimulation and pickup sites)
Stimulation site
- (-) Cathode (black): 14-cm proximal to E1 (posterolateral calf)
- (+) Anode (red): proximal
Additional Information
- Type of stimulation = Antidromic
- CPT codes for nerve conduction studies
- 95900 Nerve conduction, amplitude and latency/velocity study, each nerve; motor, without F-wave study
- 95903 Nerve conduction, amplitude and latency/velocity study, each nerve; motor with F-wave study
- 95904 Nerve conduction, amplitude and latency/velocity study, each nerve; motor with F-wave study, each nerve; sensory
- 95934 H-reflex, amplitude and latency study; record gastrocnemius/soleus muscle
- 95936 Record muscle other than gastrocnemius/soleus muscle